Better by Design

Advanced Fuel Management System FeaturesTake control of Your Diesel Fuel With An Advanced Keenan Fuel Management System

No matter if your diesel motor is used for industrial, marine, power generation, or anything else, engine reliability is critical to your operation. Since most engine problems begin with contaminated fuel, clean fuel delivery is essential to achieving that goal. That's where an advanced Keenan fuel management system comes in. Much more than a simple fuel filter, Keenan offers the only completely integrated, full-feature fuel management system available to ensure clean, dry, fuel delivery every time you start your engine. From 30 to 3000 hp, if your motor uses diesel fuel, Keenan offers a model specifically engineered to fit your needs.

Keenan Exclusive Features

PowerGen    Marine   Shop Now

Dual Filter for Non-stop Operation

Dual Filter Design With ElectRIC FilTer SwitcHing (EFS) for Non-Stop Motor Operation

The dual filter option greatly reduces the chance of surprise motor shutdowns. It allows you to switch to a clean filter with the flick of a switch using our remote EFS warning and switch panel. It also allows you to replace the dirty filter without the stopping motors. Available on all Keenen models, the dual filter option is a must have for users who can’t afford to have their motors stop during operation.

  • Allows for on-the-fly Electric Filter Switching (EFS) to clean filter
  • Easy top-loading filter element replacement
  • Available in models ranging from 60 to 1500 gallons per hour (GPH)
  • Remote Warning Panel warns of potential problems ahead of time

PowerGen    Marine   

Easy & Clean Top Load FiltersUnique Easy Access Top Loading Filter Replacement Design

All Keenan systems feature our exclusive top loading filter design. This simplifies filter changes and greatly reduces the chances of a messy fuel spill, common with ordinary bottom loading style systems. As easy as one, two, three, you simply unscrew the top, pull out the dirty fuel filter, and then drop in a new clean filter. Once the new filter is installed, the system even fills the bowl with fuel using the integrated fuel pump. 

  • Eliminates messy filter element replacement
  • Easy to remove & replace dirty filters
  • No crawling down low to replace filters
  • Integrated filling and priming
  • Helps eliminate or reduce priming

PowerGen    Marine  

Remote Warning Panel & Filter Switch

Remote Warning Panel and Electric Filter Switching

All Keenan systems are available with a Remote Warning Panel. This panel can be placed outside the engine room and will alert the operator to any potential fuel problems before it affects the engine operation. The panel and systems can also be equipped with optional Electric Filter Switching (EFS) to allow for "flick-of-switch" filter changing when a problem is detected.

  • Provides early warning of potential fuel system problems
  • Can be located outside the engine room
  • Electric Filter Switching (EFS) control also available on panel

PowerGen    Marine   

The Results of Ignoring You Diesel Fuel SystemAdvanced Fuel Filtration & Polishing Combined into one system

Keenan’s advanced diesel fuel filtration systems offer two distinct ways to ensure clean fuel delivery. First, it removes impurities to help protect the engine and warn of any potential problems during operation. Second, it preforms routine “polishing” of stored fuel to help prevent any future fuel system related issues. Together, these operations ensure your entire fuel system is moisture and contaminant free.

  • Helps keep entire fuel system clean and dry
  • Uses a lower micron prefilter for even cleaner fuel
  • Preforms routine scheduled fuel "polishing" of stored fuel
  • Removes "free water" before it damages injectors
  • Helps eliminate fuel system microbe contamination, commonly referred to as an al

PowerGen    Marine   

Remote Warning Panel & Filter Switch

mobile device GSM Monitoring and warning app (Coming Soon)

 

When you're not on location, our new KGSM8 Remote Monitoring system gives you piece-of-mind.  It will inform you how your fuel system is doing and allow you to control its operation from a mobile device. A customizable system, it can even be configured to provide control of engine room environmental systems, surveillance cameras, lights, cold weather fuel heaters, or anything else that can be set up with a digital signal output.

  • Real-time monitoring of fuel for vacuum (clogged filter) or water
  • Automatically switches to clean filter on dual filter systems using optional Electric Filter Switch (EFS) 
  • Sends message to alert technicians of system problems
  • Schedule weekly or monthly fuel polishing to ensure clean fuel storage  
  • Monitors engine room air quality for fuel, antifreeze, exhaust leaks, (VOC’S) relative humidity, barometric pressure and ambient temperature
  • Works on eight different mobile devices simultaneously 
  • Monitors battery voltage 

PowerGen    Marine   

Internal Priming & Testing

Keenan's exclusive design incorporates a system of internal passages that allow the operator to fill the filter bowls after replacement and prime the system without the use of a potentially messy external fuel source. This allows the operator to service the fuel system and get it back up and running as quickly and cleanly as possible. The system also allows you bleed and test the system before bringing it back online.

  • Internally priming
  • No need for external fuel source
  • Eliminates messy fuel spills during priming
  • Allows for off-line leak testing

PowerGen    Marine